Mechanically Fixed Terracotta Facade

A Coordinated Tile-and-Subframe Approach

TerraFix™ coordinates purpose-made terracotta facing tiles with compatible rails and brackets for mechanically fixed exterior cladding. It provides a project-specific alternative to site-bonded tile finishes while retaining the color, texture and module of fired clay.

The complete facade build-up—including the substrate, anchors, cavity, insulation, membranes, fire barriers, movement joints and edge details—must be designed and approved for each project.

Close-up of a textured terracotta facing tile engaged with a horizontal metal rail and retaining clips
Reference TerraFix™ tile and mechanical support arrangement. Final components and interfaces are project-specific.
Mechanical tile engagement
Natural fired-clay facing
Project-specific coordination
Local replacement where detailing permits

Scope and Responsibility

The Tile Is One Part of the Wall Assembly

TerraFix™ is not a universal wall assembly or a substitute for facade engineering. LOPO supplies the terracotta facing units and can provide reference component information, samples and coordination support.

The responsible project team must verify structural loads, fixing capacity, moisture management, fire performance, corrosion protection, thermal movement, tolerances and local compliance.

System Components

Coordinate the Facing, Support and Wall Interface

Each part must be selected as part of one approved project arrangement rather than treated as an independent universal component.

Zinc-aluminum-magnesium-coated horizontal steel profiles with integral tile-retaining clips

Rails, Brackets and Connections

A reference arrangement uses zinc-aluminum-magnesium-coated steel components. Material grade, coating, gauge, spacing, fasteners and connection capacity must suit the project exposure and design loads.

Red and gray textured terracotta tile samples showing rear grooves and fired-clay face finishes

Purpose-Made Facing Tiles

Fired-clay units are formed with rear geometry intended to coordinate with the selected support arrangement. Final profile, tolerances, color range, surface and corner strategy are approved through drawings and representative samples.

Wall Interface and Cavity

Anchors, substrate, isolators, insulation, membranes, cavity barriers, flashings and drainage are part of the complete wall design and are not defined by the tile alone.

Where the approved wall design includes a drained and ventilated cavity, all interfaces and compartmentation must be coordinated with the responsible project professionals.

Existing Product Reference

Reference Configuration and Nominal Data

The values below reproduce the reference configuration currently shown for this product. They are not universal design values and must be checked against the latest approved drawings, samples and supplier documents before specification or ordering.

TerraFix reference configuration and project qualification notes
ItemExisting ReferenceProject Qualification
Facing tile module244 × 68 × 17 mmNominal reference size; confirm the approved shop drawings and manufacturing tolerances.
Nominal tile coverage60.27 tiles/m²Recalculate from the approved module and include corners, openings, cutting and project allowance.
Nominal facing weight27.5 kg/m²Facing reference only; total system dead load must include rails, brackets, fasteners and accessories.
Reference horizontal profile68 × 24 × 0.6 mmReference component only; final section, gauge, spacing and connections require project engineering.
Reference steel gradeQ355B with zinc-aluminum-magnesium coatingConfirm current mill certificates, coating specification and suitability for the exposure category.
Firing temperatureApproximately 1200°CManufacturing reference only; product performance must be supported by relevant current test data.
Supporting arrangementHorizontal profiles with optional vertical profilesThe final arrangement follows the approved facade design and component supplier information.

Dimensions, coverage and weight are nominal. Joint module, tolerances, cutting, corners, openings and project allowance can change ordered quantities and installed loads.

Engineering Boundary

What Must Be Confirmed for Each Project

The final assembly must be reviewed and approved by the responsible architect, facade engineer, structural engineer, system supplier, installer and local authority, as applicable.

  • Building location, height, geometry and environmental exposure
  • Design wind, seismic and other applicable actions
  • Substrate condition and anchor capacity
  • Tile module, joints, corners, openings and tolerances
  • Cavity ventilation, drainage and moisture management
  • Insulation, membranes and fire-barrier requirements
  • Corrosion category, coating and material compatibility
  • Thermal and differential movement
  • Required mock-ups, pull-out tests or prototypes
  • Inspection, cleaning, access and replacement strategy

Material Design

Design Options for Fired-Clay Facades

LOPO can review standard or project-specific tile colors, textures and profiles, subject to manufacturing feasibility, tooling, order quantity and the approved sample range. Natural fired clay can show intended shade and texture variation, so approval should cover several units rather than one isolated sample.

Color Range

Approve a representative tonal range under relevant lighting conditions.

Surface Texture

Review texture at both close range and the intended facade viewing distance.

Tile Format

Confirm profile, module, tolerance, tooling and minimum production requirements.

Corners and Returns

Coordinate edges, openings, sills, returns and transitions in the project drawings.

Collage of residential and apartment facades clad with red terracotta facing tiles
Terracotta tile facade references illustrating color, module and corner expression.

Building Context

Typical Applications

TerraFix™ may be evaluated for commercial, residential, education, hospitality and civic facades, including selected new-build and renovation conditions.

Suitability does not follow from building type alone. Building height, location, substrate, exposure, geometry and local rules must be assessed by the project team.

Commercial and mixed-use facades
Residential developments
Education and civic buildings
Selected renovation conditions

Installation Coordination

A Project Sequence, Not a Stand-Alone Installation Manual

The exact installation procedure follows the approved system drawings, project specification, site conditions, component supplier instructions and installer method statement.

  1. Verify issued-for-construction drawings, substrate condition, tolerances and approved anchors.
  2. Set out brackets and supports in accordance with the engineered layout.
  3. Install rails, brackets and isolating components; check line, level and connection engagement.
  4. Coordinate membranes, insulation, fire barriers, flashings, cavity and drainage details.
  5. Fit the terracotta units using the approved compatible components and sequence.
  6. Inspect joints, edges, corners, fastener engagement and replacement access.
  7. Complete project QA records and any required testing or sign-off.
Partially installed red terracotta facing tiles exposing horizontal rails and retaining clips

The video illustrates a general sequence only. It does not replace approved shop drawings, structural calculations, project specifications, a site-specific method statement or installer training.

Before Full Production

Quality Control, Mock-Ups and Documentation

Before production and installation at scale, coordinate approved shop drawings, a representative color range, a project mock-up, substrate and anchor checks, component certificates and installation QA records.

Project-specific testing may include pull-out, structural, air/water, fire or other assessments required by the local design team.

Frequently Asked Questions

TerraFix™ Project Questions

Is TerraFix™ suitable for every building?

No. The concept must be evaluated against the building height, location, exposure, substrate, geometry, design loads and local requirements.

Is TerraFix™ a complete engineered facade system?

This page describes a reference tile-and-support concept. LOPO supplies terracotta products and provides product information and coordination support. Qualified project professionals must design and approve the complete wall assembly.

Can the tile size, color or surface be customized?

Custom development can be reviewed subject to manufacturing feasibility, tooling, minimum order quantity, lead time and sample approval.

Does the system require grout or sealant?

Joint treatment depends on the approved wall detail. A grout-free or open-joint approach must not be assumed solely from the tile profile.

Can individual tiles be replaced?

A mechanically fixed detail may facilitate local removal and replacement where the approved connection detail and site access allow it.

What information is needed for a project review?

Send the project country, building type and height, approximate facade area, substrate information, drawings, preferred tile module, color or surface, performance requirements and target schedule.

What test reports or certificates are available?

Request the current documents for the proposed tile and components. Document availability and relevance depend on the selected product and project requirements.

Related Resources

Project Inquiry

Discuss Your TerraFix™ Facade Project

Send the project country, building type and height, approximate facade area, substrate information, drawings, preferred tile size, color or surface and target schedule. LOPO Terracotta will review product feasibility and provide the relevant next-step information.

Email: roger@lopoterracotta.com
WhatsApp / WeChat: +86 189 5989 8697

    Fields marked * are required; other fields are voluntary. We use your information to assess and respond to your product or project inquiry and provide requested quotation, sample or technical information. If required information is not provided, we may be unable to respond. Where necessary, data may be shared with authorised LOPO personnel, relevant manufacturing or technical teams, and providers of hosting, email, forms, security and anti-spam services, including recipients outside Hong Kong. To request access to or correction of your data, email roger@lopoterracotta.com. Please do not submit sensitive personal information. See our Privacy Policy.